The RPH-260 Probe-type Residual Analyzer from Hydro Instruments provides accurate, reagentless measurement of disinfectant residuals in a wide range of water treatment and industrial applications. With the ability to operate with one or two disinfectant probes, the RPH-260 Residual Analyzer functions as both a free chlorine analyzer and a total chlorine analyzer, delivering continuous monitoring, fast response times, and built-in PID control for superior process management. As an advanced on line analyzer, it provides real-time data and can integrate directly with system controls for optimized performance.
Series RPH-260 Probe-type Residual Analyzer
Key Features of the RPH-260 Residual Chlorine Analyzer
Dual Probe Capability – Supports up to two disinfectant probes, pH electrodes, ORP electrodes, and temperature sensors for flexible monitoring. This allows the RPH-260 to operate as both a free chlorine analyzer and a total chlorine analyzer simultaneously.
Multi-Chemical Detection – Compatible with sensors for:
- Free Chlorine
- Total Chlorine
- Chlorine Dioxide
- Chlorite
- Ozone
- Hydrogen Peroxide
- Peracetic Acid
- Bromine
EPA Compliant – Meets U.S. EPA 40 CFR 141.74 and 40 CFR 141.131, Method 334.0 for on line chlorine analyzers.
Advanced Control Functions – Two independent PID control loops for set point or compound loop control. These can be paired with an automatic valve or an automatic chemical feed valve to regulate disinfectant dosing in real time.
Reliable Flow Cell Design – Gravity-fed, constant-head flow cell with bubble trap and cross-flow diverter for stable readings; pressurized flow cell available for self-cleaning probes.
Easy Operation – Graphical color display (320 x 240 resolution) and straightforward calibration.
Connectivity – Four programmable 4-20 mA outputs, four alarm relays, Modbus RS485 communication, and optional Profibus.
Data Logging – Optional logging capability with removable MicroSD card for compliance and record-keeping.
Durability – NEMA4X (IP66) rated controller suitable for demanding environments.
Performance Specifications
- Measurement Range (Free Chlorine): 0–0.5, 0–2, 0–5, 0–10, 0–20, or 0–200 PPM
- Measurement Range (Total Chlorine): 0–0.5, 0–2, 0–5, 0–10, or 0–20 PPM
- Response Time (T90): ~30 sec for Free Chlorine; ~2 min for Total Chlorine
- Sample Flow Rate: 4–8 GPH (15–30 L/h) for open flow cell; 12–24 GPH (45–90 L/h) for self-cleaning probe
- Sample Pressure: 5 PSI (0.3 bar) for open flow cell; 15 PSI (1 bar) for pressurized flow cell with cleaning head
- Resolution: 0.01 ppm or ±1% of range
- pH Measurement Range: 4–10 pH (±177 mV)
- ORP Measurement Range: ±2000 mV
- Power Requirements: 100–240 VAC (50/60 Hz) or 12–24 VDC
Applications of the RPH-260 Residual Analyzer
The Series RPH-260 Residual Chlorine Analyzer is designed for facilities where water quality and chemical control are essential:
- Municipal Water Treatment – continuous chlorine monitoring for drinking water compliance using a reagentless free chlorine analyzer.
- Fruit & Vegetable Packing – ensuring produce safety and disinfection control.
- Pharmaceutical Manufacturing – high-purity water quality control for regulatory compliance.
- Swimming Pools & Recreation – accurate chlorine measurement for public health protection with a total chlorine analyzer.
- Power Generation Facilities – controlling water chemistry in cooling and boiler systems using an on line analyzer.
For more insight into disinfection strategies, see our article on the top benefits of chlorination for water treatment.
Resources & Downloads
- RPH-260 Operations & Maintenance Manual
- Series RPH-260 Sales Bulletin
- Residual Analyzer Sensor Quick Reference Guide
- MODBUS Communication Setup Guide
For more solutions, explore Hydro Instruments’ full line of Residual Analyzers and Analyzers.
Order the RPH-260 Probe-type Residual Analyzer
When reliability, accuracy, and compliance are non-negotiable, the Series RPH-260 Residual Analyzer delivers. Contact Hydro Instruments today to request a quote and learn how our amperometric chlorine analyzers and disinfectant sensors can support your water treatment and industrial monitoring needs.
FAQs: Series RPH-260 Residual Analyzer
What is the RPH-260 Probe-type Residual Analyzer used for?
The RPH-260 is a reagentless on line analyzer that continuously measures disinfectant residuals such as free chlorine, total chlorine, ozone, and chlorine dioxide. It is widely used where accuracy, reliability, and compliance are required.
How is the RPH-260 different from the RPH-250?
The Series RPH-260 supports up to two probes, plus pH, ORP, and temperature sensors, offering more flexibility than the RPH-250. It also provides dual PID control loops, which can be connected to an automatic chemical feed valve for direct dosing control.
What chemicals can the RPH-260 Residual Chlorine Analyzer detect?
The RPH-260 functions as both a free chlorine analyzer and a total chlorine analyzer, and can also detect chlorine dioxide, chlorite, ozone, hydrogen peroxide, peracetic acid, and bromine.
Is the RPH-260 analyzer EPA compliant?
Yes. The RPH-260 Residual Analyzer complies with U.S. EPA Method 334.0 for on line chlorine analyzers, supporting regulatory monitoring of drinking water systems.
Does the RPH-260 require chemical reagents?
No. The RPH-260 uses an amperometric chlorine analyzer probe design with reagentless operation. Based on pH and temperature compensation, this technology is becoming the #1 choice for chlorine monitoring worldwide.
Where is the Series RPH-260 commonly installed?
It is installed in municipal water treatment plants, food and beverage facilities, pharmaceutical manufacturing, swimming pools, and power generation systems — anywhere a reliable on line analyzer is required.